3.3 Upper-thread sensor
Issue:
Machine stops on its own while stitching. Upper-thread breakage message appears.
But the thread is not broken.
Possible sources:
• Regulator spring is not connected with actuating lug. Therefore the actuating lug remains idle, and the
error message appears.
• Faulty upper-thread sensor signal.
Solution:
• The signal can be tested in Service Program Test 4f (upper-thread sensor).
• Hook spring to actuating lug.
• Check regulator spring position and unwinding force (see 5.11)
• Replace PCBA-Stitching head (RET) (see 4.2.8).