EasyManua.ls Logo

Bernina B 570 - Presser-Foot Pressure Stepping Motor

Bernina B 570
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BERNINA International AG Seestrasse 161 CH-8266 Steckborn Schweiz Seite 83 von 172
DRAFT VERSION
4.3.21 Presser-foot pressure stepping motor
See ESD-related note
Disassembly:
Remove the covers (see 4.1).
Picture 1 - Unplug stepping motor wire including
PFP connector (red) from PCBA-Base.
Picture 2 - Remove the two clips d.
Picture 2 - Unthread stranded wires
(yellow/green/orngae/brown) from the two spiraled
wire bundles, and remove them from the cable
duct.
Picture 3 - Remove fastening screws (T10) 1 and
2 (M3X6mm).
Carefully remove stepping motor.
Assembly:
Picture 3 - Refit stepping motor. Slightly retighten screws
1 and 2.
Picture 3 - Take care that there is no play between drive
gear pinion and wheel (no play or clamping). Then
retighten screws 1 and 2.
Picture 2 - Reinsert stranded wires into cable duct and
rethread them into spiraled wire bundles.
Picture 1 - Replug connector (red) into respective slot
labelled ‘PFP/FL red’.
If nothing else has to be taken care of, refit the covers.
Note:
Since the stepping motors don’t have connectors attached to
the motors, they must be replaced fully and including the wires
when wires are damaged.

Table of Contents