118 en | Default Configuration DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
The DiBos recorder already contains the preinstalled Web application for access via the
browser. The Web application is activated by default. If access via http is to be prevented, the
World Wide Web Publishing Service must be deactivated.
Activating/deactivating the web application:
Administrator rights are necessary for the following steps.
1. Log on to the operating system as Administrator.
2. Select Start > Control Panel.
3. Double-click the Administrative Tools icon.
4. Double-click the Internet Information Services icon.
5. Open the tree structure under Internet Information Services until you see the entry
Default Web Site.
6. Select the entry Default Web Site.
7. Start or stop the service. To do so, click the corresponding buttons.
4 Transmission rate
Limit transmission rate Activate this check box if you want to limit the transmission
rate.
Transmission rate: Select the transmission rate for DiBos-DiBos connections and
browser.
Reception rate: Select the reception rate.
5 UDP tunneling (for
firewall environments)
Allows a network connection between DiBos computers via a
single port.
Activate UDP tunneling Activate this check box when you want to permit a network
connection between DiBos computers via a fixed port.
Port number: Enter a port number that is not already used in the network.
The port number must be the same for the DiBos recorder
and the DiBos receiver.
Note:
This port must be enabled in the network. The video system's
Windows firewall must be deactivated.
Activate transmission
encryption
Activate this check box if data transmission is to be
encrypted.
Secret record: Enter a secret record of at least 10 digits. The secret record
must be the same on both computers.
6 Save The entries are saved.