46 en | Default Configuration DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
6.2.2 Setting up Dome Cameras and Pan/Tilt Cameras
Video and audio connections menu > Camera section > Edit button
Make the settings for each camera as required.
Making interface settings
1 Dome settings Click the tab.
2 Activate Select the check box if the camera is a dome camera or a
pan/tilt camera.
3 Interface The interface settings must be made first. Only then can
further dome settings follow.
Connection: Click the down arrow and select the interface (BLX = Bilinx,
GBPx = Grabber Biphase port, COMx = serial RS232 port).
Settings... Click the button. A dialog box opens. Make the settings for
the COM interface (bits per second, data bits, stop bits,
parity etc.).
The settings depend on the type of camera.
JVC: 9600/8/1/even
Panasonic 9600/8/1/none (on the Panasonic Dome, the bit
rate must be set manually)
Pelco: 2400/8/1/none
Bosch Domes: The dome settings must be saved.