EasyManua.ls Logo

Bosch DB18C3100R2 - Page 51

Bosch DB18C3100R2
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DiBos/DiBos Micro Default Configuration | en 51
Bosch Sicherheitssysteme GmbH Installation Guide F.01U.033.308 | V7 | 2009.09
6 Sensitivity Change the sensitivity if the tamper detection results are not
satisfactory.
low The sensitivity decreases, i.e. larger changes are needed for
tamper detection.
high The sensitivity increases, i.e. smaller changes are needed for
tamper detection.
Note:
Darker areas being monitored require greater sensitivity.
7 Grid - Show A grid is shown in the image when the check box is activated.
The sizes of the drawn-in areas are oriented around the grid.
8 Trigger delay Enter the time after which an alarm is triggered. A delay of
120 to 3600 seconds can be entered.
9 Set reference image Saves the live image displayed at this time as a reference
image. This reference image is used to compare all
subsequent live images.
10 Displays the reference image.
11 OK The entries are saved.