Keyswitch Zone Options
The table below lists the options available to Keyswitch Zones. If you program a zone as a
keyswitch input (Zone Type 11), program the selected Keyswitch Zone options in the location
normally used for Zone Options 1.
Option Description
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
4 Latching arm and disarm in STAY Mode 1
5 Latching arm in STAY Mode 1
6 Latching disarm from STAY Mode 1 or STAY Mode 2
8 Momentary arm and disarm in AWAY Mode
9 Momentary arm in AWAY Mode
10 Momentary disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
12 Momentary arm and disarm in STAY Mode 1
13 Momentary arm in STAY Mode 1
14 Momentary disarm from STAY Mode 1 or STAY Mode 2
0 – Latching Arm and Disarm in AWAY Mode
The system is armed or disarmed from AWAY Mode when using the latching keyswitch input.
1 – Latching Arm in AWAY Mode
The system is armed in AWAY Mode when using the latching keyswitch input. Disarming the
system is not permitted from the Keyswitch Zone.
2 – Latching Disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
The system is disarmed from AWAY Mode, STAY Mode 1, or STAY Mode 2 when using the
latching keyswitch input. Arming the system is not permitted from the Keyswitch Zone.
4 – Latching Arm and Disarm in STAY Mode 1
The system is armed or disarmed in STAY Mode 1 when using the latching keyswitch input.
Arming and disarming the system in AWAY Mode is not permitted from the Keyswitch Zone.
5 – Latching Arm in STAY Mode 1
The system is armed in STAY Mode 1 when using the latching keyswitch input. Arming the
system in AWAY Mode or disarming the system is not permitted from the Keyswitch Zone.
6 – Latching Disarm from STAY Mode 1 or STAY Mode 2
The system is disarmed from STAY Mode 1 or STAY Mode 2 when using the latching keyswitch
input. Arming the system in STAY Mode 1 or STAY Mode 2, or arming and disarming the system
in AWAY Mode is not permitted from the Keyswitch Zone.
8 – Momentary Arm and Disarm in AWAY Mode
The system is armed or disarmed from AWAY Mode when using the momentary keyswitch
input.
9 – Momentary Arm in AWAY Mode
The system is armed in AWAY Mode when using the momentary keyswitch input. Disarming the
system is not permitted from the Keyswitch Zone.
13.3.8
Control Panel Zone Information | en 103
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026