Authority Levels Description
12 Master Code and Arm/Disarm and Code Required to Isolate
14 Master Code and Arm/Disarm and Code Required to Isolate and Arm/Disarm
Reports
Table 12.1: Authority Levels
The purpose of User Codes is to arm and disarm the system and to perform other specific
functions. A Master Code holder can change or delete User Codes belongs to its partition at
any time.
User Codes 1 to 32 can be one to four digits long, but all user codes should be the same
length. Each User Code has its own priority level. More than one User Code can have the same
priority level. The priority level controls the behavior of the code, such as allowing it to arm
only, arm and disarm, or allow access to the Master Code functions. The installer can assign
access to Master Code functions to multiple User Codes. The priority level for each User Code
is programmed in the last location of the code.
Notice!
Only the installer can change the priority level.
There are 32 User Codes and 32 RF User Codes, RF User Codes can only be Remote Radio
User Codes.
Special User Code is reported when any of these methods are used to arm or disarm the
system:
– User Code 998: Arming and disarming using the A-Link Plus software.
– User Code 995: Arming remotely by telephone.
– User Code 000: Single button arming/disarming in AWAY Mode, STAY Mode 1, or STAY
Mode 2.
– User Code 997: Automatic arming/disarming in AWAY Mode or STAY Mode 1.
– User Code 994: When Arm/Disarm Tracking on Power Up selected, if the system is armed
when the system is powered down, the system returns to the armed state when the
system is powered back up.
– User Code 999: After the control panel is powered up, if the installer code is the first
code to use, the installer code can disarm the system before any partition has arm/disarm
operation.
See also
– Master Code Functions, page 51
– RF Keyfob Operations, page 59
User Code Priority
The installer can assign one of ten different priority levels to a User Code. Each priority level
allows or restricts a user from performing specific functions.
Arm/Disarm
The user can arm and disarm the system. An Arming Report is sent only after a previous code
with the ability to send a Disarming Report disarms the system.
Arm Only
12.3
Control Panel Access | en 89
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026