Page #56 background imageLoading...
Page #56 background image
This feature allows a user assigned to both areas to arm or disarm the system by pressing one
extra button on a partitioned codepad rather than entering a code on each partitioned
codepad. To enable this feature, select Option 2 in Location 501 (refer to Partitioning Options
2, page 144).
To arm or disarm both areas at the same time:
Enter your User Code and press [0][AWAY]. Two beeps sound and both areas are armed or
disarmed from AWAY Mode.
You can also arm/disarm both areas from a common codepad (assigned to both areas) with a
common user code (assigned to both areas).
Arm or Disarm Single Area
See also
Arm or Disarm Single Area, page 51
Hold-Down Functions
Hold-down functions allow easy activation of specific operations. When you hold down a
button for 2 sec, two beeps sound and the corresponding function operates.
Arm the System in AWAY Mode
Holding down [#] until two beeps sound arms the system in AWAY Mode. This hold-down
function operates only if you select Option 2 in Location 497 (refer to Consumer Options 2,
page 142).
Arm the System in STAY Mode 1
Holding down [*] until two beeps sound arms the system in STAY Mode 1. This hold-down
function operates only if you select Option 2 in Location 497 (refer to Consumer Options 2,
page 142).
If there was no alarm during the armed cycle, holding down [*] a sec time disarms the system
from STAY Mode 1. To enable single button disarming from STAY Mode 1 using this hold-down
function, select Option 4 in Location 497.
If an alarm occurred or entry warning was activated, a valid User Code is required to disarm
the system.
Refer to Zone Options 2, page 101 for information on programming each zone to be
automatically isolated in STAY Mode 1.
Arm the System in STAY Mode 2
Holding down [0] until two beeps sound arms the system in STAY Mode 2. This hold-down
function operates only if you select Option 2 in Location 497 (refer to Consumer Options 2,
page 142).
If no sound alarm occurred during the armed cycle, holding down [0] a sec time disarms the
system from STAY Mode 2. To enable single button disarming from STAY Mode 2 using this
hold-down function, select Option 4 in Location 497.
If an alarm occurred or entry warning was activated, a valid User Code is required to disarm
the system.
For more information, refer to Setting STAY Mode 2 Bypass Zones, page 47.
Notice!
STAY Mode 2 does not work on a partitioned control panel system.
7.3.2
7.4
7.4.1
7.4.2
7.4.3
56 en | System Functions Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)