AC Fail Report
An AC Fail Report (Contact ID Event Code 301) is sent to the base station receiver when the
AC MAINS supply is disconnected for 2 min. If you do not want an AC Fail Report to be sent
until the AC MAINS supply is disconnected for 1 hour, select Option 1 in Location 494.
AC Fail Restore Report
An AC Fail Restore Report is sent when the AC MAINS supply is connected continuously for
longer than 2 min.
Low Battery Report
A Battery Test Failure Report (Contact ID Event Code 302) is sent to the base station receiver
when the system’s battery voltage falls below 11 VDC or when a Dynamic Battery Test detects
a low capacity battery.
The control panel continually monitors the battery voltage. A Dynamic Battery Test is done
every time the system is armed and every 4 hours after the control panel is powered up.
Low Battery Restore Report
A Low Battery Restore Report is sent if the backup battery is restored the next time the
system is armed, or when the next Dynamic Battery Test reports the battery test is OK when
the system’s battery voltage rises to 12 VDC.
15.7.17
15.7.18
15.7.19
15.7.20
116 en | System Reporting Information Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)