3. Press [AWAY] to shift the zone indicators to indicating report events for receiver 3 and 4.
Press [STAY] to switch back to receiver 1 and 2.
4. Press and hold [9] until two beeps sound. A Test Report is sent.
To turn Report Monitor Mode off:
Enter the Installer Code and press [6][AWAY]. Two beeps sound.
Notice!
You must exit from Report Monitor Mode to resume normal operations.
Walk Test Mode
Walk Test Mode allows you to test detection devices to ensure they are functioning correctly.
Before activating Walk Test Mode, isolate any zones that are not required for testing. Refer to
Isolating zones, page 35 for more information.
To enter Walk Test Mode:
1. Enter the passcode and press [7][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash. The codepad beeps once per sec when Walk Test Mode is active.
2. Unseal and seal the zones to be tested. The codepad sounds one long beep and the horn
speaker sounds one short beep each time a zone is sealed or unsealed.
3. Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns to the disarmed state.
Event Memory Recall Mode
This function allows you to play back the last 256 system events that occurred. Event Memory
Recall Mode reports all alarms and each arming or disarming of the system , on Text LCD
Codepad, it can also helps with troubleshooting system faults. The events are displayed using
the codepad indicators.
To enter Event Memory Recall Mode:
Enter the Installer Code and press [8][AWAY]. Three beeps sound. The events are played back
by the codepad indicators in reverse chronological order.
Example
If the events occurred in the following order:
Sequence Event
1 System armed in AWAY Mode
2 Alarm in Zone 3
3 Alarm in Zone 4
4 System disarmed
5 System armed in STAY Mode
The alarm memory plays back in this order:
7.1.9
7.1.10
Control Panel System Functions | en 49
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026