Location Description Default Value Setting
033 Transmission Format 4 Domestic
034 and 039 Subscriber ID Number 0, 0, 0, 0, 0, 1 1 Beep
392 Zone Status Reporting Options 2 Receiver 2 only
403 Arm/Disarm Reporting Options 2 Receiver 2 only
424 System Status – Access Denied 6 Access Denied
427 System Status Reporting Options 2 Receiver 2 only
428 to 431,
434
Test Report Time 0, 0, 0, 0, 0 Test Reports
435 Test Reporting Options 1 Receiver 1 only
Table 5.2: Command 965 Defaults
Command 966 - Enable/Disable the Automatic Stepping of Locations
This command allows the automatic stepping of locations when programming in Installer’s
Programming Mode.
Programming with the codepad provides no visual indication that Auto Step Mode is enabled.
To enable the automatic stepping of locations:
1. Enter the Installer Code (default = 1234) and press [#] to enter Installer’s Programming
Mode. Two beeps sound and the STAY and AWAY indicators flash on the codepad to
indicate you entered Installer’s Programming Mode. The codepad displays the data stored
in Location 000.
2. Enter [9 6 6 #]. Two beeps sound.
To disable the automatic stepping of locations:
Enter [9 6 6 #]. Two beeps sound.
Example (Auto Step Enabled)
To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is enabled:
1. Press [0 #]. You are positioned at Location 000 (the Primary Telephone Number for
Receiver 1).
2. Program the number by pressing: [10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 0 * 5 * 5 * 0*]
Example (Auto Step Disabled)
To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is disabled:
Press [0 #].
You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).
To program the number, press:
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 0 *# 5 * # 5 * # 0 *]
When working with a text codepad, go to Menu 82 [Adapter auto step] to switch automatic
stepping enable/disable.
Command 999 - Display the Control Panel Firmware Version Number
When using the codepad, this command displays the firmware version of the control panel.
To display the control panel firmware version number:
1. Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s
Programming Mode. If you are using the codepad, the STAY and AWAY indicators flash to
indicate you entered Installer’s Programming Mode.
5.1.8
5.1.9
28 en | Configuration Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.