Notice!
If automatic Test Reports are not required, program the Hour/Minute/Repeat Interval in
Locations 428 to 431 and 434 as 0.
Test Reporting Options
Item Location Option Default New
Test Reporting Options 0435 0 = No report required
1 = Report to Receiver 1
2 = Report to Receiver 2
3 = Report to Receiver 3
4 = Report to Receiver 4
5 = Report to Receiver 1,2,3,4
6 = Report to Receiver 1 (2,3,4 backup)
7 = Report to Receiver 1 (2 backup) and
Receiver 3 (4 backup)
1
Location 435 is set by default to report only to Receiver 1.
Reports
Zone Tamper Report
A Zone Tamper Report (Contact ID Event Code 144) is sent when Option 14 is programmed in
Location 266 and the zone loop using split EOL resistors (3K3/6K8) with tamper (1K)
becomes open circuit.
Walk Test Report
A Walk Test Report (Contact ID Event Code 607) is sent when either the Installer or Master
Code holder activates Walk Test Mode.
Bypass Report
A zone is bypassed when it is manually isolated. A Zone Bypass Report (Contact ID Event Code
573) is sent at the end of Exit Time for any zone that was manually isolated. A 24-Hour Zone
sends a Zone Bypass Report when the zone is selected to be isolated.
A Zone Bypass Restore Report is sent when the system is disarmed. All bypassed zones are
automatically cleared when the system is disarmed.
Notice!
A 24-Hour Fire Zone that is manually bypassed reports as Contact ID Event Code 571.
Other 24-Hour Zone that is manually bypassed reports as Contact ID Event Code 572.
Trouble Report
A zone is in trouble when it is unsealed at the end of Exit Time. A Sensor Trouble Report
(Contact ID Event Code 380) is sent to indicate that one or more zones were automatically
isolated by the system.
A Sensor Trouble Restore Report is sent for Burglary Zones when the zone is resealed or the
next time the system is disarmed (whichever happens first). A 24- Hour Zone sends a restore
signal only when it is resealed.
A 24-Hour Panic Zone Trouble is reported as Contact ID Event Code 375.
15.6
15.7
15.7.1
15.7.2
15.7.3
15.7.4
Control Panel System Reporting Information | en 113
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026