EasyManuals Logo

Bosch Solution 2000 Installation Guide

Bosch Solution 2000
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
Notice!
If automatic Test Reports are not required, program the Hour/Minute/Repeat Interval in
Locations 428 to 431 and 434 as 0.
Test Reporting Options
Item Location Option Default New
Test Reporting Options 0435 0 = No report required
1 = Report to Receiver 1
2 = Report to Receiver 2
3 = Report to Receiver 3
4 = Report to Receiver 4
5 = Report to Receiver 1,2,3,4
6 = Report to Receiver 1 (2,3,4 backup)
7 = Report to Receiver 1 (2 backup) and
Receiver 3 (4 backup)
1
Location 435 is set by default to report only to Receiver 1.
Reports
Zone Tamper Report
A Zone Tamper Report (Contact ID Event Code 144) is sent when Option 14 is programmed in
Location 266 and the zone loop using split EOL resistors (3K3/6K8) with tamper (1K)
becomes open circuit.
Walk Test Report
A Walk Test Report (Contact ID Event Code 607) is sent when either the Installer or Master
Code holder activates Walk Test Mode.
Bypass Report
A zone is bypassed when it is manually isolated. A Zone Bypass Report (Contact ID Event Code
573) is sent at the end of Exit Time for any zone that was manually isolated. A 24-Hour Zone
sends a Zone Bypass Report when the zone is selected to be isolated.
A Zone Bypass Restore Report is sent when the system is disarmed. All bypassed zones are
automatically cleared when the system is disarmed.
Notice!
A 24-Hour Fire Zone that is manually bypassed reports as Contact ID Event Code 571.
Other 24-Hour Zone that is manually bypassed reports as Contact ID Event Code 572.
Trouble Report
A zone is in trouble when it is unsealed at the end of Exit Time. A Sensor Trouble Report
(Contact ID Event Code 380) is sent to indicate that one or more zones were automatically
isolated by the system.
A Sensor Trouble Restore Report is sent for Burglary Zones when the zone is resealed or the
next time the system is disarmed (whichever happens first). A 24- Hour Zone sends a restore
signal only when it is resealed.
A 24-Hour Panic Zone Trouble is reported as Contact ID Event Code 375.
15.6
15.7
15.7.1
15.7.2
15.7.3
15.7.4
Control Panel System Reporting Information | en 113
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)

Related product manuals