Page #141 background imageLoading...
Page #141 background image
If selected, the control panel keeps its current armed status in non-volatile memory. If the
control panel is restarted due to a power failure, the control panel returns to being armed or
disarmed as it was before the power failed.
Example
If the system is disarmed when the system is powered down, the system returns to the
disarmed state when the system is powered back up.
System Option 5
Item Location Option Default New
System Options 5 0110 1 = Domestic Dial Fail to Report
2 = Installer Arm/Disarm Function
4 = Reserved
8 = Reserved
0
1 - Domestic Dial Fail to Report
If this option is selected, a Communication Fail Report (Contact ID Event Code 354) is
automatically sent when Domestic Dialing fails once the control panel is set up for domestic.
If this option is not selected, the CommFail Report is not sent when Domestic Dialing fails.
2 - Installer Arm/Disarm Function
If this option is selected, it is allowed to use installer command [Code][9][#] to arm/disarm
the system in AWAY mode, or [Code][9][*] to arm/disarm the system in STAY 1 mode.
If this option is not selected, it is not allowed to use install command [Code][9][#] or [Code]
[9][*] to arm/disarm the system.
Consumer Options 1
Item Location Option Default New
Consumer Options 1 0496 1 = Test reports only when armed
2 = Test report after siren reset
4 = Auto arm in STAY Mode 1
8 = STAY indicator to display day alarm status
0
1 – Test Reports Only When Armed
If this option is selected, Test Reports (Contact ID Event Code 602) are only sent when the
system is armed. It is no longer necessary to send a Test Report with an Arm/Disarm Report
every day.
Most commercial premises are open during the working week, so a Test Report is not
necessary because Arm/Disarm Reports are sent at the programmed time. If you want to
manually send a Test Report, press and hold [9] button until two beeps sound.
Refer to Test Reporting Time, page 112 to set the desired Test Report time. To set the first Test
Report, refer to Set the Number of Days until the First Test Report, page 45.
2 – Test Report after Siren Reset
Select this option to force the control panel to send a Test Report (Contact ID Event Code
601) after the siren is reset. This can be used to indicate to the monitoring station that the
control panel itself was not tampered with during the alarm period.
4 – Auto Arm in STAY Mode 1
Select this option if automatic arming in STAY Mode1 is preferred to automatic arming in
AWAY Mode.
18.5
18.6
Control Panel System and Consumer Options | en 141
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)