EasyManuals Logo

Bosch Solution 2000 Installation Guide

Bosch Solution 2000
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
System Options 2
Item Location Option Default New
System Options 2 0493 1 = Codepad panic to be silent
2 = Codepad fire to be silent
4 = Codepad medical to be silent
8 = Access denied (code retries) to be silent
0
1 – Codepad Panic to Be Silent
If this option is selected, a Codepad Panic Alarm or Radio Remote Panic Alarm does not
operate the horn speaker, the bell, or the strobe outputs. If this option is not selected, all
three outputs operate after a Codepad Panic Alarm is activated when a user presses [1] and
[3] or [STAY] and [AWAY] at the same time on the remote codepad. Selecting this option does
not affect the operation of the communication report.
2 – Codepad Fire to Be Silent
If this option is selected, a Codepad Fire Alarm does not operate the horn speaker, the bell, or
the strobe outputs. If this option is not selected, all three outputs operate after a Codepad
Fire Alarm is activated when a user presses [4] and [6] at the same time on the remote
codepad. Selecting this option does not affect the operation of the communication report.
4 – Codepad Medical to Be Silent
If this option is selected, a Codepad Medical Alarm does not operate the horn speaker, the
bell, or the strobe outputs. If this option is not selected, all three outputs operate after a
Codepad Medical Alarm is activated when a user presses [7] and [9] at the same time on the
remote codepad. Selecting this option does not affect the operation of the communication
report.
8 – Access Denied (Code Retries) to Be Silent
If this option is selected, a Codepad PIN Error Alarm does not operate the horn speaker, bell,
or the strobe outputs. If this option is not selected, all three outputs operate after a Codepad
PIN Error Alarm occurs. Selecting this option does not affect the operation of the
communication report. If you want to disable the reporting of Access Denied reports, program
Locations 424 as 0.
System Options 3
Item Location Option Default New
System Options 3 0494 1 = AC fail after 1 hr. (Disabled = after 2 min.)
2 = Ignore AC fail
4 = Pulse count handover allowed
8 = Handover delay to be sequential
8
1 – AC Fail after 1 Hour
If this option is selected, the MAINS indicator flashes when the AC MAINS supply is
disconnected. An AC Loss signal (Contact ID Event Code 301) is transmitted to the base
station receiver after the AC MAINS supply is disconnected continuously for longer than 60
min.
If this option is not selected, the MAINS indicator flashes and an AC Loss signal (Contact ID
Event Code 301) is transmitted to the base station receiver after the AC MAINS power is
disconnected continuously for 2 min.
18.2
18.3
Control Panel System and Consumer Options | en 139
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)