10 – Momentary Disarm from AWAY Mode, STAY Mode 1, or STAY Mode 2
The system is disarmed from either AWAY Mode, STAY Mode 1, or STAY Mode 2 when using
the momentary keyswitch input. Arming the system is not permitted from the Keyswitch Zone.
12 – Momentary Arm and Disarm in STAY Mode 1
The system is armed or disarmed in STAY Mode 1 when using the momentary keyswitch input.
Arming and disarming the system in AWAY Mode is not permitted from the Keyswitch Zone.
13 – Momentary Arm in STAY Mode 1
The system is armed in STAY Mode 1 when using the momentary keyswitch input. Arming the
system in AWAY Mode or disarming the system is not permitted from the Keyswitch Zone.
14 – Momentary Disarm from STAY Mode 1 or STAY Mode 2
The system is disarmed from STAY Mode 1 or STAY Mode 2 when using the momentary
keyswitch input. Arming the system in STAY Mode 1 or STAY Mode 2, or arming and disarming
the system from AWAY Mode is not permitted from the Keyswitch Zone.
Wiring Diagram for Keyswitch Zone
Wiring Diagram for Keyswitch Zone Using
Split EOL with Tamper
1
2
Z1 COM Z2
Z1 COM Z2
1
2
1 – EOL
2 – Keyswitch (Momentary/Toggle)
1 – EOL
2 – Keyswitch (Momentary/Toggle)
Table 13.2: Wiring Diagram for Keyswitch Zone
Zone Source
Zone source is a new feature for zone programming. It defines the zone/input is onboard zone,
or RF zone, or expanded B228 zone. Defaulted zone source is Onboard.
Zone Source for zone 1 to 16 are stored in Location 0754 to 0769.
For Solution 2000, only Onboard zone is available.
For Solution 3000, select Option 0 or 1 for Zone 1 - 8; select Option 0, or 1, or 2 for Zone 9 -
16.
Option Description
0 Onboard
1 RF
2 B228
Swinger Shutdown Count for Siren
Item Location Option Default New
Swinger Shutdown Count
For Siren
0379 1 – 15 = Number of times siren operates
until lockout
3
13.3.9
13.4
104 en | Zone Information Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away