Page #50 background image
Sequence Indicator On Event
1
2 , ,
Stay armed by User 2
2
1 ,
Disarmed by User 1
3
4 ,
Alarm in Zone 4
4
3 ,
Alarm in Zone 3
5
2 , ,
AWAY armed by User 2
Each event is indicated by a beep every 2 second and a lit indicator. You can also press [STAY]
key to review the previous event.
After the last event, three beeps sound to indicate the end of playback. You can stop the
replay at any time by pressing [AWAY].
When working with a text codepad, the events are played back automatically after entered
event memory recall mode. And you can also page up or page down manually to review the
events. You can stop the replay at any time by pressing [AWAY].
Notice!
If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator shows the event
memory playback. There is no differentiation between STAY Mode 1 and STAY Mode 2.
If the control panel is powered down, the memory of all events is saved.
AWAY/STAY 1 Arm/Disarm
This function allows you to arm/disarm the system in AWAY mode or in STAY 1 mode with the
installer code.
To arm the system in AWAY mode:
1. Enter the Installer Code and press [9][AWAY].
2. Two beeps sound, the AWAY indicator lights, and Exit Time starts.
To disarm the system from AWAY Mode:
1. Enter the Installer Code and press [9][AWAY].
2. Two beeps sound and the AWAY indicator is extinguished.
To arm the system in STAY Mode 1:
1. Enter the Installer Code and press [9][STAY].
2. Two beeps sound and the STAY indicator is lit. Exit Time starts.
To disarm the system from STAY Mode 1:
1. Enter the Installer Code and press [9][STAY].
2. Two beeps sound and the STAY indicator is extinguished. The system is now disarmed.
7.1.11
50 en | System Functions Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)