Horn Speaker Test
Holding down [1] until two beeps sound activates the horn speaker for a 2-sec burst. No other
sounding device operates during this mode.
Bell Test
Holding down [2] until two beeps sound activates the internal screamers for a 2-sec burst. No
other sounding device operates during this mode.
Strobe Test
Holding down [3] operates the strobe. No other device operates during this mode.
To turn the strobe test on:
Press and hold [3] until three beeps sound. The strobe flashes.
To turn the strobe test off:
Press and hold [3] until two beeps sound. The strobe stops flashing.
Turning Day Alarm On and Off
Holding down [4] turns Day Alarm on or off. If you want the STAY indicator to indicate the
status of Day Alarm operation (enabled or disabled), select Option 8 in Location 496 (refer to
Consumer Options 1, page 141). When this option is selected, the STAY indicator flashes once
every 3 sec when Day Alarm is active.
To turn Day Alarm on:
Press and hold [4] until three beeps sound.
To turn Day Alarm off:
Press and hold [4] until two beeps sound.
Fault Analysis Mode
Several system faults can be detected by the control panel. When any of these faults are
present, the FAULT indicator flashes and the codepad beeps once per minute. Refer to Fault
descriptions, page 37 for more information.
To determine the type of fault:
Press and hold [5] until two beeps sound.
The STAY and AWAYindicators flash. One or more zone indicators (1 to 16) light to indicate the
type of fault that occurred.
To exit from Fault Analysis Mode:
Press [AWAY].
The STAY and AWAY indicators are extinguished and the system returns to the disarmed state.
Initiate a Modem Call
Holding down [6] until two beeps sound forces the control panel to dial the callback
telephone number programmed in Locations 159 to 174 in an attempt to connect to the
installer’s remote computer.
The remote computer must be running the A-Link Software and must be set to Waiting for an
Incoming Call. If no callback telephone number is programmed, holding down [6] has no
effect.
See also
Call Back Telephone Number, page 75
7.4.4
7.4.5
7.4.6
7.4.7
7.4.8
7.4.9
Control Panel System Functions | en 57
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)