To arm the system in STAY Mode 2:
1. Press and hold [0].
2. When two beeps sound, release the button. The STAY indicator is lit and the Exit Time
starts.
The indicators for any zones that are programmed to be automatically isolated in STAY Mode 2
flash until the Exit Time expires. At the end of Exit Time, the zone indicators are extinguished
and the codepad sounds one short beep.
If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and is lit
constantly on the remote codepad. The zone becomes an active part of the system again as
soon as it is resealed. For example, if a window is open when Exit Time expires, the window
does not become an active part of the system until it is closed. Opening the window after Exit
Time expires causes an alarm.
Forced Arming
Arming the system when a zone is not sealed is known as forced arming. Refer to Zone Options
2, page 101 to enable forced arming for each zone.
If the STAY indicator does not light and a long beep sounds when attempting to arm the
system, forced arming is not permitted. If this is the case, you must seal all zones or manually
isolate them before you can arm the system.
Disarming the system from STAY Mode 2
There are two methods to disarm the system from STAY Mode 2. You can always use the first
method. You can use method two only if Option 4 is enabled in Location 497 (refer to
Consumer Options 2, page 142 ).
To disarm the system from STAY Mode 2 (method one):
1. Enter your code and press [STAY].
2. Two beeps sound and the STAY indicator is extinguished. The system is now disarmed.
To disarm the system from STAY Mode 2 (method two):
A flashing zone indicator represents a previous alarm in that zone. If this is the case, a valid
User Code is required to disarm the system using method one. To enable method two, Option
4 in Location 497 must be enabled.
1. Press and hold [0].
2. When two beeps sound, release the button. The STAY indicator is extinguished and the
system is disarmed.
Notice!
Single button disarming from STAY Mode 2 reports as User Code 00.
Codepad duress alarm
A codepad Duress Alarm is used as a silent holdup alarm when 9 is added to the end of a valid
User Code being used to disarm the system.
A Duress Alarm (Contact ID Event Code 121) is useful only if your system reports to a
monitoring station because domestic reporting format cannot decipher the type of alarm that
occurred. You can select Option 2 in Location 498 to use 3 instead of 9 to activate a Duress
Alarm (refer to Consumer Options 3, page 143).
Codepad panic alarm
An audible codepad Panic Alarm activates when a user presses either [1] and [3] or [STAY]
and [AWAY] simultaneously.
6.6
6.7
6.8
34 en | System Operations Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)

Related product manuals