Callout - Description
1 – Control panel
2 – Terminal wiring
3 – Codepad’s wiring terminal block
Installer Menu
Use the menu tree below to program the control panel from the IUI-SOL-TEXT codepad. To
program the control panel from the IUI-SOL-ICON, use the programming address indicated in
brackets [ ] next to each command as shown in the Menu Tree.
Example:
To program Exit Time using the IUI-SOL-TEXT
Method 1: By Text Menu
1. Enter the Installer Code, followed by [-] or [#] key (for example, [1234#]),
2. Then press keys [3], [1], [3] to enter [Exit time] and program the exit time.
Method 2: By address programming
1. Enter the Installer Code, followed by [-] or [#] key (for example, [1234#]),
2. Press [8] [1] to enter address programming.
3. Press [470 #] to enter Exit Time address to program.
To program Exit Time using the IUI-SOL-ICON
Enter the Installer Code followed by [#] key, then press [470 #] to enter Exit Time address to
program.
4.1.1
16 en | Accessories Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)