If Zone 2 activates an alarm, the Swinger Shutdown Count for Zone 2 is incremented to 1.
Swinger Shutdown Count for Zone 1 is still 5. If Zone 1 reactivates again, it locks out Zone 1
from activating the report. When smart lockout is enabled, if any zone activates the siren
before siren running time is expired, Zone 1 reactivates and can still send a report.
STAY Mode 2 Automatically Bypass Zones
STAY Mode 2 Automatically Bypass Zones can be programmed in Location 381 - 384. It can
also be done by master code function. Refer to Setting STAY Mode 2 Bypass Zones, page 47 for
more information.
Zone 9 – 16 is only for Solution 3000.
Item Location Option Default New
STAY Mode 2
Automatically Bypass
Zones
0381 1 = Zone 1
2 = Zone 2
4 = Zone 3
8 = Zone 4
0
0382 1 = Zone 5
2 = Zone 6
4 = Zone 7
8 = Zone 8
0
0383 1 = Zone 9
2 = Zone 10
4 = Zone 11
8 = Zone 12
0
0384 1 = Zone 13
2 = Zone 14
4 = Zone 15
8 = Zone 16
0
Zone Status Reporting Options
Item Location Option Default New
Zone Status Reporting
Options
0392 0 = No Zone status reports allowed
1 = Report to Receiver 1
2 = Report to Receiver 2
3 = Report to Receiver 3
4 = Report to Receiver 4
5 = Report to Receiver 1,2,3,4
6 = Report to Receiver 1 (2,3,4 backup)
7 = Report to Receiver 1 (2 backup) and
Receiver 3 (4 backup)
1
This location is set by default to report only to Receiver 1.
13.6
13.7
106 en | Zone Information Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)