Master Code Functions
Master Code functions allow those users that have the appropriate priority level to perform
certain supervisory level functions. You can use these functions only when the system is
disarmed.
Notice!
The default Master Code (User Code 1) is 2580. It is possible to program multiple Master
Codes. Refer to User Code Priority, page 89 for more information.
To access a Master Code function, enter the Master Code and press the corresponding
function digit and the [AWAY] button. Except the Master Code functions listed in the table
below, Master Code functions also allows the users to arm or disarm single area.
Function Description
0 Arm or disarm both areas at the same time
1 Add, change and delete user codes / remote radio user codes (RF keyfobs)
2 Change domestic phone numbers
3 Change Telco arm/disarm sequence
4 Set bypass zones for STAY Mode 2
5 Turn outputs on and off
6 Set the date and time
7 Walk test mode
8 Event memory recall mode
9989 System reset
Table 7.3: Master Code Functions
Arm or Disarm both Areas at the Same Time
This Master Code function only operates with partitioned control panel systems and allows
Master Codes allocated to both Area 1 and Area 2 to arm or disarm both areas at the same
time.
This feature allows a Master Code holder to arm or disarm the system by pressing one extra
button rather than entering a code twice. You can use any area codepad by a User Code
assigned to both areas with this function. To enable this feature, select Option 2 in Location
501 (refer to Partitioning Options 2, page 144).
To arm or disarm both areas at the same time:
Enter your Master Code and press [0][AWAY]. Two beeps sound and both areas are armed or
disarmed from AWAY Mode.
Arm or Disarm Single Area
This Master Code function allows to arm or disarm single area with any codepad.
7.2
7.2.1
7.2.2
Control Panel System Functions | en 51
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026