Codepad Lockout Time
Item Location Option Default New
Codepad Lockout Time 0478 0 = No lockout
1 – 15 = Lockout time 10 – 150 sec.
(Increments of 10 sec.)
0
All codepads are locked out for the programmed time if an invalid code is entered more times
than allowed by the code retry attempts programmed in Location 424. If the Codepad Lockout
Time is programmed as 0, codepad lockout does not occur.
See also
Access Denied, page 111
Siren Run Time
Item Location Option Default New
Siren Run Time 0479 0 = No Siren time
1 – 15 = Siren time 1 – 15 min. (increments of
1 min.)
5
The Siren Run Time determines how long the horn speaker/siren operates during an alarm.
You can program the Siren Run Time from 0 to 15 min in 1-min intervals.
Siren Sound Rate
Item Location Option Default New
Siren Sound Rate 0480 0 = Slowest frequency
15 = Fastest frequency
7
The Siren Sound Rate varies the frequency of the siren tone slowest (0) and to fastest (15).
The Siren Sound Rate does not change the frequency of the fire alarm tone.
Auto Arming Pre-Alert Time
Item Location Option Default New
Auto Arming Pre-Alert Time 0481 0 = No alert time
1 – 15 = Alert time 5 – 75 min.
(increments of 5 min.)
1
This location sets the time period during which the control panel warns you it is automatically
armed in AWAY Mode. The codepad beeps once every second until the Pre-Alert Timer expires:
the system then automatically arms itself in AWAY Mode. If you want the system to
automatically arm in STAY Mode 1, enable Option 4 in Location 496 (refer to Consumer
Options 1, page 141).
After the control panel is automatically armed in AWAY Mode or STAY Mode 1, Exit Time starts.
If a valid User Code is entered during the Pre-Alert Time, the Auto Arming Time programmed in
Locations 482 to 485 is extended by 1 hour.
If you want a programmable output to operate during the Auto Arming Pre-Alert Time, use
Output Event Type 0,5 Auto Arm Pre-Arming Alert Time.
See also
Auto Arming Time, page 137
17.8
17.9
17.10
17.11
136 en | System Event Timers Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)