The user can arm the system but cannot disarm the system. An Arming Report is sent only
after a previous code with the ability to send a Disarming Report disarms the system.
Arming/Disarming Reports
Arming/Disarming Reports are sent to the monitoring station when the user disarms and arms
the system.
Code To Isolate
If one or more User Codes include this option, the method of standard isolating is disabled
and only a User Code with this option in its priority level can isolate zones before arming the
system using the Code to Isolate method. Refer to Isolating zones, page 35.
Notice!
When priority level 4, 6, 12, or 14 is assigned to any User Codes, the Standard Isolating
method no longer operates. Only User Codes with a priority level of 4, 6, 12, or 14 can isolate
zones using the Code to Isolate method.
Master Code Functions
Master Code functions allow those users that have the appropriate priority level to perform
certain supervisory level functions. You can use these functions only when the system is
disarmed.
Notice!
The default Master Code (User Code 1) is 2580. It is possible to program multiple Master
Codes
To access a Master Code function, enter the Master Code and press the corresponding
function digit and the [AWAY] button. The Master Code functions are listed in below table.
Function Description
0 Arm or disarm both areas at the same time
1 Add, change, and delete User Codes/Remote Radio User Codes
2 Change domestic phone numbers
3 Change Telco Arm/Disarm Sequence
4 Set bypass zones for STAY Mode 2
5 Turn outputs on and off
6 Set the date and time
7 Walk Test Mode
8 Event Memory Recall Mode
9989 System reset
Table 12.2: Master Code Functions
See also
Master Code Functions, page 51
90 en | Access Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)