This polarity is normally open circuit and switches to pulsing 0 V when the event occurs. The
output switches back to open circuit when the event is restored. Time parameters vary the On
time (Time base) and Off time (Time Base*Time Base Multiplier) of the pulse.
3 – Normally Open, One-Shot Low
This one-shot polarity is normally open circuit and switches to 0 V when the event occurs. The
output switches back to open circuit when the time parameter setting expires. This one-shot
time setting always runs its full duration and cannot be manually reset.
4 – Normally Open, One-Shot Low with Reactivate
This one-shot polarity is normally open circuit and switches to 0 V when the event occurs.
Every time the event occurs, it restarts the one-shot timer. The output switches back to open
circuit when the oneshot time expires. This one-shot time setting always runs its full duration.
You cannot reset the time.
5 – Normally Open, One-Shot Low with Reset
This one-shot polarity is normally open circuit and switches to 0 V when the event occurs. The
output switches back to open circuit when the one-shot time expires or when the event
returns to normal.
6 – Normally Open, One-Shot Low with Alarm
This one-shot polarity is normally open circuit and switches to 0 V when the event occurs. The
output switches back to open circuit when the one-shot time expires, the event returns to
normal.
This polarity is ideally suited for the operation of strobe lights because you can program the
lights to reset (up to 99 hours) and prevent them from burning out or bothering others due to
prolonged operation.
7 – Normally Open, Latching Low
This polarity is normally open circuit and switches to 0 V when the event occurs. The output
switches back to open circuit when a user holds down [7] on the remote codepad until two
beeps sound. Time parameters do not apply to this polarity.
8 – Normally Low, Going Open
This polarity is normally 0 V and switches to open circuit when the event occurs. The output
switches back to 0 V when the event is restored. Time parameters do not apply to this
polarity.
9 – Normally Low, Pulsing Open
This polarity is normally 0 V and switches to pulsing open circuit when the event occurs. The
output switches back to 0 V when the event is restored. Time parameters vary the Off time of
the pulse. (Time base) and On time (Time Base*Time Base Multiplier) of the pulse.
10 – Normally Low, One-Shot Open
This one-shot polarity is normally 0 V and switches to open circuit when the event occurs. The
output switches back to 0 V when the time parameter expires. This one-shot time setting
always runs its full duration and cannot be manually reset.
11 – Normally Low, One-Shot Open with Reactivate
This one-shot polarity is normally 0 V and switches to open circuit when the event occurs.
Every time the event occurs, it restarts the one-shot timer. The output switches back to 0 V
when the one-shot time expires. This one-shot time setting always runs its full duration. You
cannot reset the time.
12 – Normally Low, One-Shot Open with Reset
This one-shot polarity is normally 0 V and switches to open circuit when the event occurs. The
output switches back to 0 V when the one-shot time expires or when the event returns to
normal.
13 – Normally Low, One-Shot Open with Alarm
Control Panel
Programmable Outputs | en 131
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)

Related product manuals