Zone Type Description
10 Reserverd
11 Keyswitch
12 24-Hour Burglary
13 24-Hour Fire
14 Chime Only
15 Not Used
0 – Instant Zone
When the Country Code is set as Australia (refer to Country Codes, page 73), an Instant Zone
(Contact ID Event Code 130) immediately sounds the sirens and sends the zone alarm reports
if it is unsealed after the Exit Timer expires.
Arming Report is sent after the Exit Timer expires.
If an Instant Zone is not restored when the time the system is disarmed, a Zone Restore
Report is automatically sent to the receiving party.
1 – Handover Zone
A Handover Zone (Contact ID Event Code 130) acts as an Instant Zone if it is activated by
itself. If a Handover Zone is activated after a Delay Zone, the remaining Delay Time is handed
over from the Delay Zone to the Handover Zone.
Handover can be sequential or non-sequential. The default settings is sequential handover.
You can disable sequential handover by disabling Option 8 in Location 494 (refer to System
Options 3, page 139).
Handover Zone is not restored when the system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
2 – Delay-1 Zone
A Delay-1 Zone (Contact ID Event Code 130) has a delay time determined by the value in
Locations 466 and 467 (refer to Entry Time 1, page 134). After Entry Time expires, the system
activates an alarm.
If a Delay-1 Zone is not restored when the system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
3 – Delay-2 Zone
A Delay-2 Zone (Contact ID Event Code 130) has a delay time determined by the value in
Locations 468 and 469 (refer to Entry Time 2, page 134). After Entry Time expires, the system
activates an alarm.
If a Delay-2 Zone is not restored when the system is disarmed, a Zone Restore Report is
automatically sent to the receiving party.
6 – 24-Hour Medical Zone
A 24-Hour Medical Zone (Contact ID Event Code100) is always ready to activate the horn
speaker, bell, and strobe, whether the system is armed or disarmed. A Medical Report is
transmitted to the base station receiver. A 24-Hour Medical Zone does not send a Restore
Report until the zone is restored.
7 – 24-Hour Panic Zone
A 24-Hour Panic Zone (Contact ID Event Code 120) is always ready to activate the horn
speaker, bell, and strobe, whether the system is armed or disarmed. A Panic Report is
transmitted to the base station receiver. A 24-Hour Panic Zone does not send a Restore
Report until the zone is restored.
98
en | Zone Information Control Panel
2017.10 | 03 | F.01U.298.026 Installation Guide Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)