3-23
Confidential
■ NO TRAY XX
If feed from the T2/T3, the T1/T2 in the paper path is not installed.
■ PRINT OVERRUN
Print date capacity is flooded the memory capacity of machine.
■ REPLACE DRUM
Drum unit is the time for replacement.
Replace the drum unit.
■ REPLACE FUSER
Fuser unit is the time for replacement.
■ REPLACE LASER
Laser unit is the time for replacement.
<User Check>
- Install the T1 or T2.
Step Cause Remedy
1
Harness connection failure of PE
EG sensor ASSY of T1 or T2
Check the sensor performance following
the procedure in "Factory Inspection Mode"
in 1.3 Service Mode in Chapter 7.
If any problem occurs, check the harness
connection of the PE EG sensor ASSY.
2 LT PCB ASSY failure Replace the LT PCB ASSY.
3 Connector 55533-1219 Replace the connector 55533-1219.
4
PE EG sensor ASSY of T1 or T2
failure
Replace the PE EG sensor ASSY of the T1
or T2.
5 Main PCB ASSY failure Replace the main PCB ASSY.
<User Check>
- Reduce the complexity of data or reduce the print resolution.
- Add on the DIMM.
Step Cause Remedy
1
Fuser unit is the time for
replacement
Replace the fuser unit and reset the
counter. (Refer to "2.2 Reset Parts Life
Menu" in Chapter 7.)
Step Cause Remedy
1
Laser unit is the time for
replacement
Replace the laser unit and reset the
counter. (Refer to "2.2 Reset Parts Life
Menu" in Chapter 7.)