12. FUNCTION SETTING METHODS
SL-710A
83
12-3. Parameters
The parameter numbers appear on the panel.
Parameter No.10 - 33
Parameter No. Default value Data value setting range Function
10 15 (150 ms) 00 - 25 [X10] (0 - 250 ms)
Time delay from the time the machine starts to operate
with the automatic presser foot raised to the time the
moter operates.
11 05 (50 ms) 03 - 10 [X10] (30 - 100 ms)
Time delay from the time the thread wiper turns OFF
until the automatic presser foot turns ON
12 *1
(From design
change B onward)
03 01 - 10
Time from when lower thread solenoid finally turns
OFF to when motor can operate
13 30 (300 ms) 10 - 90 [X 10] (100 - 900 ms)
Time to keep the automatic presser foot lifter raised
14 (a) 36 (3 min) 00 - 60 [X 5] (5sec - 5 min)
The presser foot signal will be automatically off after the
set time passes. When the data is set to 00, the presser
foot signal is not automatically off.
15 (b) 00 (30ms) 00 - 60 [X 2.5] (0 - 150 ms)
Time from the
p
resser foot lowerin
g
command to
when the presser foot momentarily turns ON
16 12 10 - 12 Detection voltage constant from the presser foot
lowering command to when the presser foot
momentarily turns ON
17 10 (10s) 05 - 30 (5 - 30 s) Continuous puller ON time
18 40 (40 stitches) 00 - 99 (0 - 99 stitches) Number of stitches from sewing start to lowering of
puller
20 02 (20ms) 01 - 07 [X10] (10 - 70ms) Time delay from end of thread trimming to the time
when thread wiper turns ON
21 05 (50ms) 04 - 10 [X10] (40 - 100ms) Thread wiper ON time
22 50 (50ms) 40 - 70 [X1] (40 - 70ms) Lower thread detect pin ON control time (all areas)
23 10 (10ms) 05 - 25 [X1] (5 - 25ms) First ON time for lower thread detect pin
24 07 (7ms) 01 - 15 [X1] (1 - 15ms) First OFF time for lower thread detect pin
26 03 (30ms) 00 - 05 [X10] (0 - 50ms) Time delay from the time the thread wiper turns OFF to
the time when the lower thread detect pin turns ON
27 (c) 05 (0.5s) 02 - 50 [X0.1] (0.2 - 5.0s) Time dela
y
from the time when the machine sto
p
s
with the needle at its hi
g
hest/lowest
p
osition to the
lower thread detect
p
in ON
(
Lower thread detection
function at the needle u
p
/down sto
p
with the foot
pedal in neutral)
30
-04 (-60
°
)
-23 to +23 (units of 15°)
(- appears as "-", and +
appears as " ".)
ON timin
g
for
q
uick reverse device durin
g
start
backtacking and continuous backtacking
31
00 (0
°
)
-23 to +23 (units of 15°)
(- appears as "-", and +
appears as " ".)
OFF timin
g
for
q
uick reverse device durin
g
start
backtacking and continuous backtacking
32
+02 (30
°
)
-23 to +23 (units of 15°)
(- appears as "-", and +
appears as " ".)
OFF timin
g
for
q
uick reverse device durin
g
end
backtacking.
33 (d)
-04 (-60
°
)
-23 to +23 (units of 15°)
(- appears as "-", and +
appears as " ".)
2nd ON timin
g
for
q
uick reverse device durin
g
double end backtacking
*1 ... Values are X10 ms.
Notes
(a) The timer-off function for the presser foot is activated only when memory switch 36 is set to off.
(b) The indicated parameters are only enabled when memory switch 35 is set to ON.
(c) The lower thread detection function for the needle up/down stop when the pedal is positioned at neutral is activated
only when memory switch 51is set to on.
(d) The indicated parameters are the settings when memory switch 22 is set to ON.
1834M