EasyManua.ls Logo

Brother S-710A - Page 91

Brother S-710A
153 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12. FUNCTION SETTING METHODS
SL-710A
84
Parameter No.P0 - S5
Parameter
No.
Default value Data value setting range Function
P0 00 (0 mm) -07 - 07 [X0.25]
(-1.75 - 1.75 mm)
Thread trimmer operating point of depression stroke
P1 -01 (-0.25 mm) -05 - 05 [X0.25]
(-1.25 - 1.25 mm)
Back automatic presser lifter operating point of
depression stroke
P2 01 (0 mm) -05 - 05 [X0.25]
(-1.25 - 1.25 mm)
Forward automatic presser lifter operating point of
depression stroke
P3 00 (0 mm) -05 - 05 [X0.25]
(-1.25 - 1.25 mm)
Low speed start operating point of depression stroke
P4 00 (0 mm) -05 - 05 [X0.25]
(-1.25 - 1.25 mm)
Speed change starting point of depression stroke
P5 00 (0 mm) -06 - 06 [X0.75]
(-4.5 - 4.5 mm)
Maximum speed reaching point of depression stroke
S4 -01 (-0.25 mm) -02 - 02 [X0.50]
(-1.0 - 1.0 mm)
Speed change starting point of standing operation
variable speed pedal
S5 00 (0 mm) -02 - 02 [X0.50]
(-1.0 - 1.0 mm)
Maximum speed reaching point of standing operation
pedal
With the value being 0 at the treadle neutral position, the value is positive when the treadle is depressed forward, and
negative when the treadle is depressed backward. The value is added to or deducted from the standard setting value.
(Refer to page 91 for details.)
(Example 1: Changing setting for P0)
(Example 2: Changing setting for P3)
(Example 3: Changing setting for P5)
1
835
M
1836M
1837M
Neutral
Speed
Depression stroke
Speed
Neutral
Depression stroke
Speed
Depression stroke
Neutral

Table of Contents

Related product manuals