III - 21
[ 15 ]Disassembling the Movable Sensor PCB ASSY
(1) Release the two hooks to remove the sensor holder A from the sensor holder A2.
(2) Remove the sensor cover from the sensor holder A.
(3) Remove the RT sensor PCB ASSY from the sensor holder A2, and pull out the
harness of the RT sensor PCB ASSY from the hole of the sensor holder A2.
(4) Push the latch to remove the sensor plate from the sensor holder A2.
Figure 3.4-19
Sensor holder A
Sensor cover
Hook
Sensor holder A2
Hook
RT sensor PCB ASSY
Latch
Sensor plate
Hole