2006 Buell Lightning: Electrical 7-13
HOME
DIAGNOSTICS
The reference numbers below correlate with the circled num-
bers in the 7.5 STARTER INTERLOCK flow charts.
1. Check diode polarity as shown in Figure 7-11.
2. Check diode with an ohmmeter as shown in Figure 7-12.
Figure 7-11. Diode Polarity
b0644x4x
TN/Y
Diode Polarity
TN/LTGN
Terminal (40)
Terminal (34)
Figure 7-12. Ohmmeter Diode Test
Continuity Infinite
ohms
b0643x4x
Figure 7-13. Diode Wiring
1
2
21
22
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
2
6
7
10
87
87A
30
85
86
23
RELAY
CENTER
ISO
ISOISO
KEY SW.
IGNITION
START
39
40
41
42
43
44
33
34
35
36
37
38
21
22
23
24
25
26
28
29
30
31
32
27
Spare
Diode
Bk/Hn/Mflr
Fan
IGN
Acces.
Key Sw
Lights
ECM
Spare
Empty
Battery
Neutral
Switch
TN/LTGN
Start
Relay
Diode
TN/Y
BK
b1107c7x
Clutch
Switch
[131A]
[95B]
[131B]
[95A]
TN/LTGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Buell 2006LIGHTNING MODELS and is the answer not in the manual?

Buell 2006LIGHTNING MODELS Specifications

General IconGeneral
BrandBuell
Model2006LIGHTNING MODELS
CategoryMotorcycle
LanguageEnglish

Related product manuals