245I-Modell - 11/12 - Ausgabe 09/11 - 2096165 - BUE-0056-05EN
Troubleshooting
14
No voltage is supplied by
the living area battery
Living area battery is dis-
charged
Charge living area bat-
tery immediately
Z Total discharge
damages the
battery.
If the vehicle is to be laid
up for a long period, fully
charge the living area
battery beforehand
Discharging is caused by
inactive appliances (see
chapter 8)
The 12 V indicator lamp
does not light up or there
is no display on the panel
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Starter or living area bat-
tery is not charged
Charge the starter or liv-
ing area battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Flat fuse (2 A) in the liv-
ing area battery is defec-
tive
Replace flat fuse (2 A) in
the living area battery
Extractor hood does not
work
230 V automatic circuit
breaker is switched off
Switch on the 230 V au-
tomatic circuit breaker
Fuse (15 A) at the trans-
former/rectifier is defec-
tive
Replace fuse (15 A)
Extractor hood defective Contact customer service
Fault Cause Remedy