251I-Modell - 11/12 - Ausgabe 09/11 - 2096165 - BUE-0056-05EN
Troubleshooting
14
14.8.2 Dometic 8 series with AES
"GAS" indicator lamp
flashes yellow, no gas
Air in the gas pipe Switch off the refrigera-
tor with energy selector
switch
Open regulator tap on
the gas bottle and the
gas isolator tap of the re-
frigerator
Switch on the refrigera-
tor with energy selector
switch. After 10 seconds,
the AES will attempt an-
other ignition
If the "GAS" indicator
lamp flashes yellow
again after approx.
30 seconds, the failure
has not been remedied
yet
Repeat this process two
to three times for ventila-
tion. If the refrigerator
cannot be operated, con-
tact customer services
Z In the case of a fault the LED display fault will always light up " ".
Fault Cause Remedy
Text "230 V" flashes No 230 V power supply Connect 230 V power
supply
230 V automatic circuit
breaker has triggered
Switch on the 230 V au-
tomatic circuit breaker
230 V operating voltage
too low
Have the 230 V power
supply checked by an au-
thorised specialist work-
shop
Text "12 V" flashes Fuse on the transformer/
rectifier is defective
Replace fuse on the
transformer/rectifier
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V operating voltage
too low
Have the 12 V power
supply checked by an au-
thorised specialist work-
shop
Fault Cause Remedy