Cadex Electronics Inc. C7000-C Series Battery Analyzers .
Detailed
Message
Code Reasons Solutions
BATTERY OVER
TEMP
14
Battery has overheated during
charge. Station goes to
Resting 00:00 (code 19) until
the battery cools.
Reduce the Charge rate in the C-
Code.
If using a non-OEM battery, the
battery thermistor may be
incorrect for the adapter.
Contact Cadex to upgrade the
adapter.
BATTERY
OVERCHARGED
178
Current program completed;
battery SoC (State of Charge)
is too high.
Discharge the battery for 10
minutes and then charge again.
Verify that correct contacts are
used.
Battery may have a high internal
resistance. Verify with OhmTest
and discard the battery.
HOT BATTERY ON
TRICKLE CHARGE
159
Battery temperature has
exceeded its maximum setting
after service has ended and
battery was on trickle charge.
The trickle charge stops.
Verify that the mAh rating of the
battery matches the C-Code mAh
setting.
Reduce the Charge rate in the C-
Code. Reduce the trickle-charge
rate or the maximum standby
voltage in the extended C-Code.
Lower the room temperature.
BATTERY REMOVED
17
Battery was removed when the
program completed.
This message appears briefly
when the battery is removed. If
message persists, press
ESC
.
BATTERY REMOVED
26
A five-second delay after the
battery is removed when the
program completed.
If message persists, press
ESC
.
BATTERY REVERSED
121
Battery voltage too low (less
than 0.30V/cell) on insertion.
Battery may be connected
backwards in the adapter.
Ensure that battery leads are
firmly connected to the battery.
Apply a Boost.