123
Detailed
Message
Code Reasons Solutions
CELL MISMATCH
112
For NiCd or NiMH batteries
only. Cells are reaching full
charge at different times so
the negative slope is not well
defined. The program
proceeds to the next cycle.
Wait until processing is complete
because the Auto and Prime
programs will attempt to correct
this warning through several
more charge and discharge
cycles. If corrected, code 192
(Cell mismatch corrected)
appears.
Reduce the negative slope in
extended C -Code to 8mV/cell.
Battery is old or has been in
storage. Operating time may be
reduced. Either monitor battery
use or discard the battery.
If the battery is new, use the
Prime program.
CELL MISMATCH
CORRECTED
192
Cell mismatch (code 112) is
corrected through several
charge/discharge cycles.
Use the battery as normal.
HOT BATTERY
/
HEAT
TERMINATION
158
Midway during charge the
temperature went above the
maximum set in the C-Code.
Program resumed when
battery cooled by 5°C. A WAIT
code may appear for the
battery to cool before the next
process begins.
See code 154, Charge complete
temp rise. Reduce charge rate if
problem persists (see page 45).
CHARGE CURRENT
LOW
164
Current driver cannot provide
the requested charge current
See code 160, Bad fuses or
driver.
CHARGE CYCLE
COMPLETE
30
Charge cycle completed. Program is going to the next
step.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cadex Electronic C7000-C Series and is the answer not in the manual?

Cadex Electronic C7000-C Series Specifications

General IconGeneral
BrandCadex Electronic
ModelC7000-C Series
CategoryMeasuring Instruments
LanguageEnglish