Detailed
Message
Code Reasons Solutions
DCHG CYCLE
COMPLETE
31
Discharge cycle completed. Program is going to the next
step.
DISCHARGE
CURRENT LOW
162
The analyzer cannot discharge
the battery. Very low values of
current (< 50mA) are
displayed on the analyzer
before this code appears
(See code 160, Bad fuses or
driver).
DISCHARGE
TIMEOUT
142
Battery capacity has exceeded
250% of the rated capacity.
Verify that the mAh rating of the
battery matches the C-Code mAh
setting.
Raise the discharge rate in the
extended C -Code.
DISCHARGE WAIT
6
Station is on hold until
sufficient power is available.
Wait until other stations have
completed battery service.
DISCHARGING
7
Battery is being discharged
normally.
Program will continue when cycle
has completed.
HIGH CELL
RESISTANCE
135
Battery resistance has
exceeded the OhmTest
setpoint threshold
Program is complete (see To
edit the OhmTest Setpoint, page
31).
HIGH CELL
RESISTANCE
136
The battery resistance has
exceeded the OhmTest
setpoint threshold – this
message is for BatteryShop
Program is complete (see To
edit the OhmTest Setpoint, page
31).
HOT BATTERY
,
LOW
VOLTAGE
156
Battery temperature went to
its maximum setting in the
initial charge cycle. Service
terminates.
Reduce the Charge rate in the C-
Code. Allow battery to cool
before servicing the battery
again.
The internal cells may have
shorted or the battery is old.
Either monitor battery use or
discard.