Configuring 60 GHz cnWave™ 149
Figure 156:
The Internet Protocol Version 4 (TCP/IPv4) dialog box
5. Enter a subnet mask of 255.255.0.0. Leave the default gateway blank.
Connecting to the PC and powering up
Use this procedure to connect a management PC and power up the 60 GHz cnWave devices.
Procedure:
1. Check that the ODU is connected to the power supply (AC/DC according to the configuration).
2. Connect the PC Ethernet port to the LAN port of the PSU or AUX port (according to device
configuration).
3. Open a web browser and type: 169.254.1.1.
4. When prompted, enter admin/admin to login to the GUI and complete the configuration.
Using the web interface
This section describes how to log into the 60 GHz cnWave web interface and use its menus.
Logging into the web interface
Use this procedure to log into the web interface as a system administrator.
Procedure:
1. Start the web browser from the management PC.
2. Type the IP address of the unit into the address bar. The factory default IP address is 169.254.1.1
and press Enter.