EasyManua.ls Logo

Cameron Scanner 3100 EFM - Page 16

Cameron Scanner 3100 EFM
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 1.1—General Specications
Supported
Meter Types
Turbine meter
Cone meter
Orice meter
Ultrasonic meter
Positive displacement (PD) meter
Coriolis meter
Venturi meter
Download Types Per Device Complete (all records, including slave device records as
applicable)
Local (integral ow records in a condensed le ideal for
emailing)
Events
Triggered (one-second logs, including PID tuning)
Per Flow Run Daily
Interval (hourly)
Event
Recent (past 7 days of interval logs)
Per Slave Daily
Interval (hourly)
Recent (past 7 days of interval logs)
Archive
Capacity
Up to 58 archivable parameters per ow run
Daily log capacity 2,048 days
Interval log capacity 2.8 years with 13 parameters (plus date, time and status)
logged hourly
Capacity varies with the number of parameters logged (13 to
58) and logging frequency (1 second to 12 hours)
Triggered log capacity
(1 to 19 parameters)
1,351,680 logs with one parameter logged;
135,168 logs with 19 parameters logged
Congurable to log periodically (1 second to 12 hours) on
a real-time period (daily, weekly, etc.) on device alarm, on
digital input, or when activated remotely via the web browser
Event log capacity 98,304 records
Downloadable via FTP, HTTP (web interface), or Enron Modbus protocol (see Scanner Data
Manager User Manual for information on viewing data les)
Logs stored in non-volatile memory for up to 10 years
Communications/
Archive Retrieval
Wireless Optional SmartMesh wireless radio module available with or
without external antenna. See Table 1.2—Hardware Options,
page 20.
Wired RS-485 Two dedicated ports (1 and 2) and one shared RS-485/RS-
232 port (3)
Software-selectable 120-ohm termination resistor
Selectable master and slave protocols (Enron Modbus,
Modbus RTU, Modbus TCP)
Wired RS-232 Shared RS-485/RS-232 port (port 3)
TXD, RXD, RTS, CTS
Time-of-day digital output conguration
16
Section 1 Scanner 3100 EFM

Table of Contents