HAZARDOUS AREA
N-FEMALE CONNECTOR
ANTENNA COUPLER (NO SEAL REQUIRED)
PART NO. 2350765-01 (CSA - NORTH AMERICA)
PART NO. 76533628 (ATEX)
CONNECTS TO
WIRELESS
MODULE
INSIDE
SCANNER 3100
ENCLOSURE
DIRECT-MOUNT ANTENNA
PART NO. 2350869-01
N-MALE CONNECTOR
Figure 2.4—Installation requirements for a direct-mount Cameron-supplied antenna
HAZARDOUS
AREA
(CSA - NORTH AMERICA)
MAX. CAPACITANCE: 60 pF/ft (196 pF/m)
MAX. INDUCTANCE: 2µH/ft (6.5 µH/m)
N-FEMALE CONNECTOR
ANTENNA COUPLER (NO SEAL REQUIRED)
PART NO. 2350765-01 (CSA - NORTH AMERICA)
PART NO. 76533628 (ATEX)
CONNECTS TO
WIRELESS
MODULE
INSIDE
SCANNER 3100
ENCLOSURE
REMOTE ANTENNA
PART NO. 50279275
OR EQUIVALENT DESIGN WITH
GAIN OF 10 dBI OR LESS
(CSA - NORTH AMERICA)
MAX. CAPACITANCE: 200 pF
MAX. INDUCTANCE: 100 nH
(ATEX)
MAX. CAPACITANCE: 50 pF
MAX. INDUCTANCE: 20 nH
N-FEMALE CONNECTOR
MAX. 30 FT (9.1 M)
MALE-TO-MALE CABLE
(ATEX)
MAX. CAPACITANCE: 23.9 pF/ft (78.4 pF/m)
MAX. INDUCTANCE: 0.060 µH/ft (0.20 µH/m)
Figure 2.5—Installation requirements for a remote-mount antenna
FCC Radio Frequency Compliance
Scanner 3100s that include the optional SmartMesh radio module comply with Federal Communications Commission
(FCC) radio frequency (RF) exposure compliance requirements when the following requirements are met.
Important To comply with FCC and IC RF exposure compliance requirements, the antenna must be installed
to provide a separation distance of at least 20 cm from all persons. Changes or modications to
the installation that violate this requirement and are not authorized by the radio manufacturer
could void your authority to operate the equipment.