© Cesab 8 – 17 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:002
The motor control
unit temperature
exceeds +85°C.
The motor control
is limiting the
voltage
1: Cooling is
reduced or the
temperature
sensor is
defective.
1: Check the cooling
• Check the cooling flanges of the
transistor regulator, motor and
steering motor as well as the
battery charger and fans and
filters for accumulations of dirt
and dust. Too much dust and dirt
cause the cooling not to work
properly.
• Check that the fans work when
the speed control is activated
(fans behind T1 and motor fan)
• Check that the fan on charger
T14 works when the charging
starts, i.e. when the mains cable
is connected
• Check the signal from the
temperature sensors for T1 and
T13 and from B1 using the
integrated test or TruckCom.
Determine if the temperature
signals are plausible relative to
the real temperatures of the
components. If not, replace
T1,T13 or replace B1 with a
repair kit.
3:040
Incorrect power
saving function in
the standby
mode.
Not influenced
1: Internal error
in T1
1: Restart the truck.
2: If the error persists, replace
the motor control T1.
Code Description
Truck
behaviour
Error cause(s) Procedure