© Cesab 8 – 19 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:081
The motor
temperature sensor
is outside of limit
values. Above
210°C.
Creep speed and
motor control
limits the voltage.
1: Cooling is
reduced or the
temperature
sensor is
defective.
1: Check the cooling
• Check the cooling flanges of the
transistor regulator, motor and
steering motor as well as the
battery charger and fans and
filters for accumulations of dirt
and dust. Too much dust and dirt
cause the cooling not to work
properly.
• Check that the fans work when
the speed control is activated
(fans behind T1 and motor fan)
• Check that the fan on charger
T14 works when the charging
starts, i.e. when the mains cable
is connected
• Check the signal from the
temperature sensors for T1 and
T13 and from B1 using the
integrated test or TruckCom.
Determine if the temperature
signals are plausible relative to
the real temperatures of the
components. If not, replace
T1,T13 or replace B1 with a
repair kit.
3:100
Motor control
warning. Unknown
warning
Creep speed,
blocked lifting/
lowering
movement
1: Internal
program error
2: Software
failure
1: Create a truck report. Send a
report to the manufacturer.
2: Update the truck software to
the latest version.
3:101 Internal error in T1
Creep speed,
blocked lifting/
lowering
movement
1: The motor
control is
using pre-set
power
amplification.
Internal error
1: Restart the truck.
2: If the error persists, replace
the motor control T1.
3:120
Incorrect checksum
for the motor
control parameters
Creep speed,
blocked lifting/
lowering
movement
Motor control corrupt
1: Update the truck software to
the latest version.
2: Replace T1
Code Description
Truck
behaviour
Error cause(s) Procedure
https://www.forkliftpdfmanuals.com/