© Cesab 8 – 20 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:121
The motor control
T1 cannot use
internal memory.
Creep speed,
blocked lifting/
lowering
movement
Internal error in T1
1: Restart the truck.
2: Update the truck software
• Update the truck entire software
package to the latest available
version.
3: If the error persists, replace T1
3:140
Hardware
protection in T1
detects a short
circuit in the output
for the horn. The
current through the
horn is above the
valid limit value.
Maximum value =
500mA, continuous
value = 300mA
Not influenced
High power
consumption or
short circuit
1: Check for overcurrent or short
circuit:
• Check the ohms and the
amperes of the component,
compare them to the setpoint
values if they outside the
accepted range.
• Check the connections and
wiring harness for short-circuit.
• Check that the component does
not seize or is jammed.
• If points 1-3 are OK, it indicates
that the output stage is short
circuited - Replace the power-
supplying component
Code Description
Truck
behaviour
Error cause(s) Procedure
https://www.forkliftpdfmanuals.com/