© Cesab 8 – 25 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:531 Internal error in T1
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
1: Software
failure
2: Defective
motor control
1: Update the truck software to
the latest version.
2: Replace T1
3:532 Internal error in T1
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
The motor
control has
detected an
internal problem
in the AD
converter.
Replace T1
3:533
The charging
voltage for the
motor control
capacitor indicates
abnormal values.
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
The charging
voltage for the
motor control
capacitor
indicates
abnormal
values.
1: Check:
connections and wiring harness
Wire 20
The connection point (T1:84)
must be 24 V
Motor controller
Pump contactor
2: If the error persists, replace T1
3:535
Incorrect checksum
for the motor
control parameters.
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
Incorrect
checksum for
the motor
control
parameters.
1: Update the truck software
Update the truck entire software
package to the latest available
version.
3:537 Internal error in A5
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
Multi-direction
command
issued by
handle.
What to do?
Code Description
Truck
behaviour
Error cause(s) Procedure