© Cesab 8 – 34 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
4:102
Signal from the
sensilift
potentiometer
detected even
though parameter
1102 does not have
the value 4.
Creep speed,
blocked lifting/
lowering
movement
1: Incorrect value
for parameter
1102
2: Error in
hydraulic
controls
1: Check parameters
Check that factory parameters
are set according to the truck
configuration.
Check that other parameters
are set correctly.
2: Replacement of the hydraulic
control.
4:125
Pump motor
current feedback
remains zero when
the pump motor
operates.
Creep speed,
blocked lifting/
lowering
movement
1: Defective
power supply
to the motor
control.
Replace T1
4:126
Excessive pump
motor current
feedback at start-
up and in the
standby mode.
Creep speed,
blocked lifting/
lowering
movement
1: Defective
power supply
to the motor
control.
Replace T1
4:521
Pump motor
voltage too low.
The main
contactor opens
1: Wire break
between T1
and the pump
motor
2: The pump
motor
1: Check wiring after the break.
Disconnect the battery
Using instruments, check that
there is no break in any wire.
Measure and check the voltage
with the functions activated
2: Check the pump motor
Disconnect motor wiring
including sensor wires.
Insulation test. Check that the
coils are not electrically
connected to the chassis.
Replace if the motor is not
isolated
Code Description
Truck
behaviour
Error cause(s) Procedure