© Cesab 8 – 33 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:597
The motor
temperature
exceeds +180°C.
The drive is
stopped
immediately with
the parking brake
1: Intensive use
of the truck
2: Cooling is
reduced or the
temperature
sensor is
defective.
1: Intensive use of the truck. Let
the truck cool down.
2: Check the cooling
• Check the cooling flanges of the
transistor regulator, motor and
steering motor as well as the
battery charger and fans and
filters for accumulations of dirt
and dust. Too much dust and dirt
cause the cooling not to work
properly.
• Check that the fans work when
the speed control is activated
(fans behind T1 and motor fan)
• Check that the fan on charger
T14 works when the charging
starts, i.e. when the mains cable
is connected
• Check the signal from the
temperature sensors for T1 and
T13 and from B1 using the
integrated test or TruckCom.
Determine if the temperature
signals are plausible relative to
the real temperatures of the
components. If not, replace
T1,T13 or replace B1 with a
repair kit.
4:001
Lifting/lowering
control is not in
neutral position at
start-up. Lifting is
prevented until the
lifting/lowering
controller is back in
the neutral position.
Blocked lifting/
lowering
movement
1: Control
manipulated
1: Let go of the control, and wait
for four seconds
2: Check
• wiring in the handle
• the potentiometer. If defective,
replace the potentiometer.
4:101
Signal from the
sensilift
potentiometer
detects abnormal
values.
Creep speed,
blocked lifting/
lowering
movement
1: Control
manipulated
1: Let go of the control, and wait
for four seconds
2: Check
• wiring in the handle
• the potentiometer. If defective,
replace the potentiometer.
Code Description
Truck
behaviour
Error cause(s) Procedure