EasyManuals Logo

CESAB S210 User Manual

CESAB S210
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
© Cesab 8 – 42 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
8:136
Overvoltage in the
li-ion battery
Creep speed,
blocked lifting
movement
1: A module in
the battery has
been switched
off because its
voltage is too
high.
1: Restart the battery.
8:137
Battery cells
deactivated by
internal monitoring
Creep speed,
blocked lifting
movement
1: Some battery
functions are
not working.
1: Overvoltage, undervoltage,
temperature too high,
temperature too low. Let the
battery rest and then restart
the battery.
8:138
Low battery voltage
in the li-ion battery
Creep speed,
blocked lifting
movement
1: Battery
discharged
2: Voltage drop.
1: Charge the battery
2: Check battery voltage
Check the voltage using the
built-in test procedure and
comparing with value from
external volt meter
Check connectors, joints and
splices for damage or corrosion.
Check fuses F1 and F50
8:139
Wrong battery type
selected via
parameter 1045
Creep speed,
blocked lifting
movement
1: Battery
parameter
1045 has
incorrect
setting.
1: Check parameters
Check that factory parameters
are set according to the truck
configuration.
Check that other parameters
are set correctly.
Code Description
Truck
behaviour
Error cause(s) Procedure
https://www.forkliftpdfmanuals.com/

Table of Contents

Other manuals for CESAB S210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CESAB S210 and is the answer not in the manual?

CESAB S210 Specifications

General IconGeneral
BrandCESAB
ModelS210
CategoryTrucks
LanguageEnglish

Related product manuals