© Cesab 8 – 42 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
8:136
Overvoltage in the
li-ion battery
Creep speed,
blocked lifting
movement
1: A module in
the battery has
been switched
off because its
voltage is too
high.
1: Restart the battery.
8:137
Battery cells
deactivated by
internal monitoring
Creep speed,
blocked lifting
movement
1: Some battery
functions are
not working.
1: Overvoltage, undervoltage,
temperature too high,
temperature too low. Let the
battery rest and then restart
the battery.
8:138
Low battery voltage
in the li-ion battery
Creep speed,
blocked lifting
movement
1: Battery
discharged
2: Voltage drop.
1: Charge the battery
2: Check battery voltage
• Check the voltage using the
built-in test procedure and
comparing with value from
external volt meter
• Check connectors, joints and
splices for damage or corrosion.
• Check fuses F1 and F50
8:139
Wrong battery type
selected via
parameter 1045
Creep speed,
blocked lifting
movement
1: Battery
parameter
1045 has
incorrect
setting.
1: Check parameters
• Check that factory parameters
are set according to the truck
configuration.
• Check that other parameters
are set correctly.
Code Description