CG Drives & Automation,01-5326-01r5 Functional Description 111
Communication information
Over temperature [252]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
Over volt D [253]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active
.
Communication information
Over volt G [254]
Delay time starts counting when the fault is gone When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
Over volt [255]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
251 No of Trips
Default: 0 (no Autoreset)
Range: 0–10 attempts
Modbus Instance no/DeviceNet no: 43071
Profibus slot/index 168/230
EtherCAT and CANopen index (hex) 4bff
Profinet IO index 19455
Fieldbus format UInt, 1=1
Modbus format UInt
NOTE: An auto reset is delayed by the remaining
ramp time.
252 Over temp
Default: Off
Off 0 Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no: 43072
Profibus slot/index 168/231
EtherCAT and CANopen index (hex) 4c00
Profinet IO index 19456
Fieldbus format Long, 1=1 s
Modbus format EInt
NOTE: An auto reset is delayed by the remaining
ramp time.
253 Over volt D
Default: Off
Off 0 Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no: 43075
Profibus slot/index 168/234
EtherCAT and CANopen index (hex) 4c03
Profinet IO index 19459
Fieldbus format Long, 1=1 s
Modbus format EInt
NOTE: An auto reset is delayed by the remaining
ramp time.
254 Over volt G
Default: Off
Off 0 Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no: 43076
Profibus slot/index 168/235
EtherCAT and CANopen index (hex) 4c04
Profinet IO index 19460
Fieldbus format Long, 1=1 s
Modbus format EInt
255 Over volt
Default: Off
Off 0 Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no: 43077
Profibus slot/index 168/236
EtherCAT and CANopen index (hex) 4c05
Profinet IO index 19461
Fieldbus format Long, 1=1 s
Modbus format EInt