210 CG Drives & Automation, 01-5326-01r5
11.9.3 Stored values [730]
The shown values are the actual values built up over time.
Values are stored at power down and updated again at power
up.
Run Time [731]
Displays the total time that the AC drive has been in the
Run Mode.
Communication information
Reset Run Time [7311]
Reset the run time counter. The stored information will be
erased and a new registration period will start.
Communication information
Mains time [732]
Displays the total time that the AC drive has been connected
to the mains supply. This timer cannot be reset.
Communication information
Energy [733]
Displays the total energy consumption since the last energy
reset [7331] took place.
Communication information
Reset Energy [7331]
Resets the energy counter. The stored information will be
erased and a new registration period will start.
Communication information
731 Run Time
Unit: h: mm:ss (hours: minutes: seconds)
Range: 00: 00: 00–262143: 59: 59
Modbus Instance no/DeviceNet no:
31028:31029:31030
(hr:min:sec)
Profibus slot/index
121/172:121/173: 121/
174
EtherCAT and CANopen index (hex) 2404:2405:2406
Profinet IO index 1028:1029:1030
Fieldbus format Long, 1=1h:m:s
Modbus format Eint
7311 Reset RunTm
Default: No
No 0
Yes 1
Modbus Instance no/DeviceNet no: 7
Profibus slot/index 0/6
EtherCAT and CANopen index (hex) 2007
Profinet IO index 7
Fieldbus format UInt
Modbus format UInt
NOTE: After reset the setting automatically reverts to
“No”.
732 Mains Time
Unit: h: mm:ss (hours: minutes: seconds)
Range: 00: 00: 00–262143: 59: 59
Modbus Instance no/DeviceNet no:
31031:31032:31033
(hr:min:sec)
Profibus slot/index
121/175:121/176: 121/
177
EtherCAT and CANopen index (hex)
2407 : 2408 :
2409
Profinet IO index 1031:1032:1033
Fieldbus format Long, 1=1h:m:s
Modbus format Eint
733 Energy
Unit: Wh (shows Wh, kWh, MWh or GWh)
Range:
0.0–1GWh,
Counter will restart at 0 after 1GWh
Modbus Instance no/DeviceNet no: 31034
Profibus slot/index 121/178
EtherCAT and CANopen index (hex) 240a
Profinet IO index 1034
Fieldbus format Long, 1=1 Wh
Modbus format EInt
7331 Rst Energy
Default: No
Selection: No, Yes
Modbus Instance no/DeviceNet no: 6
Profibus slot/index 0/5
EtherCAT and CANopen index (hex) 2006
Profinet IO index 6
Fieldbus format UInt
Modbus format UInt
NOTE: After reset the setting automatically goes back
to “No”.