EasyManuals Logo

CG Emotron VFX Series User Manual

CG Emotron VFX Series
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #245 background imageLoading...
Page #245 background image
CG Drives & Automation 01-5326-01r5 Technical Data 243
14.3 Operation at higher
temperatures
Most Emotron AC drives are made for operation at
maximum of 40 °C (104 °F) ambient temperature.
Frame sizes C69/D69/C2(69)/D2(69) are rated at 45 °C
(113 °F). However, it is possible to use the AC drive at
higher temperatures with reduced output rating.
Possible derating
Derating of output current is possible with
-1% / degree Celsius to max +15 °C * (= max temp 55 °C) or
-0.55%/ degree Fahrenheit to max +27 °F
(= max temp. 131 °F).
* max +10 °C for sizes C69/D69/C2(69)/D2(69).
Example
In this example we have a motor with the following data that
we want to run at the ambient temperature of
45 °C (113 °F):
Voltage 400 V
Current 72 A
Power 37 kW (50 hp)
Select AC drive
The ambient temperature is 5 °C (9 °F) higher than the
maximum ambient temperature. The following calculation
is made to select the correct AC drive model.
Derating is possible with loss in performance of
1%/°C (0.55%/ degree F).
Derating will be: 5 x 1% = 5%
Calculation for model VFX48-074
74 A - (5% x 74) = 70.3 A; this is not enough.
Calculation for model VFX48-090
90 A - (5% x 90) = 85.5 A
In this example we select the VFX48-090.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CG Emotron VFX Series and is the answer not in the manual?

CG Emotron VFX Series Specifications

General IconGeneral
BrandCG
ModelEmotron VFX Series
CategoryController
LanguageEnglish

Related product manuals