CG Drives & Automation,01-5326-01r5 201
Counter 2 High value [6623]
Function is identical to Counter 1 High value [6613].
Communication information
Counter 2 Low value [6624]
Function is identical to Counter 1 Low value [6614].
Communication information
Counter 2 Decrement timer [6625]
Function is identical to Counter 1 Decrement timer [6615].
Communication information
Counter 2 Value [6629]
Parameter shows the actual value of counter 2.
Communication information
6623 C2 High Val
Default: 0
Range: 0 - 10000
Modbus Instance no/DeviceNet no: 43583
Profibus slot/index 170/232
EtherCAT and CANopen index (hex) 4dff
Profinet IO index 19967
Fieldbus format Long, 1=1
Modbus format EInt
6624 C2 Low Val
Default: 0
Range: 0 - 10000
Modbus Instance no/DeviceNet no: 43584
Profibus slot/index 170/233
EtherCAT and CANopen index (hex) 4e00
Profinet IO index 19968
Fieldbus format Long, 1=1
Modbus format EInt
6625 C2 DecTimer
Default: Off
Off 0 Off
1 - 3600 1 - 3600 1 - 3600 s
Modbus Instance no/DeviceNet no: 43585
Profibus slot/index 170/234
EtherCAT and CANopen index (hex) 4e01
Profinet IO index 19969
Fieldbus format Long, 1=1 s
Modbus format EInt
NOTE: Counter 2 value is common for all parameter
sets.
NOTE: The value is volatile and lost at power down.
6629 C2 Value
Default: 0
Range: 0 - 10000
Modbus Instance no/DeviceNet no: 42928
Profibus slot/index 168/87
EtherCAT and CANopen index (hex) 4b70
Profinet IO index 19312
Fieldbus format UInt, 1=1
Modbus format UInt