CS35 2013.04
3.1.13-89 3.1.13-89Electronic Control System - ME7
Acceleration pedal potentiometer 2 volt-
age
0.4 V 0.4 V 0.5 V
Two times the voltage of the acceleration
pedal potentiometer 2
0.8 V 0.8 V 0.9 V
Internal resistance of the post - catalytic
oxygen sensor
0.0 hm 0.0 hm 800 hm
Upstream catalytic converter exhaust
temperature
50.0 ℃ 358.1 ℃ 510.6 ℃
Air mass flow rate 0.0 kg/h 0.0 kg/h 0.0 kg/h
Injection time 0.0 ms 0.2 ms 0.1 ms
Static idle target speed 740 rpm 720 rpm 720 rpm
Cylinder 1 postpone ignition knock control 0.0 ° 0.0 ° 0.0 °
Cylinder 2 postpone ignition knock control 0.0 ° 0.0 ° 0.0 °
Cylinder 3 postpone ignition knock control 0.0 ° 0.0 ° 0.0 °
Cylinder 4 postpone ignition knock control 0.0 ° 0.0 ° 0.0 °
Reference voltage for cylinder 1 knock
control
0.977 V 0.135 V 0.245 V
Reference voltage for cylinder 2 knock
control
0.977 V 0.157 V 0.274 V
Reference voltage for cylinder 3 knock
control
0.977 V 0.156 V 0.484 V
Reference voltage for cylinder 4 knock
control
0.977 V 0.148 V 0.327 V
Mileage with fault lamp enabled 0 km 0 km 0 km
Coolant temperature during start
71.3 ℃ 91.5 ℃ 91.5 ℃
Standard air charge calculated by canis-
ter control
0.0 kg/h 0.121 kg/h 0.0 kg/h
Basic ignition angle 0 ° 29 ° 41 °
Number statistic of misfire cylinder 0 0 0
1st cylinder misfire number 0 0 0
2nd cylinder misfire number 0 0 0
3rd cylinder misfire number 0 0 0
4th cylinder misfire number 0 0 0
Misfire range under the minimum load 0.0 % 0.0 % 0.0 %
Misfire range under the maximum load 0.0 % 0.0 % 0.0 %
Lambda mandatory regulation cycle 34,304 8,192 58,924
Data Flow Item Ignition Switch ON Idle Running
Engine Rotate
Speed 2,500
rpm
mashinesoft.com